Modelling IFC-SG for Structural Submission

Modelling IFC-SG for Structural Submission

Structural Parameters
IFC-SG PropertyList

BeamSpanType

•Single
•End
•Interior
•Cantilever

ConnectionTypeBottom, ConnectionTypeTop, LeftConnectionType, or RightConnectionType 

•Pinned
•Fixed
•Free

ConstructionMethod

•CIS
•PC
•PT (Pre)
•PT (Post)
•PF
•PPVC
•Spun [for pile element only]

MaterialGrade

•C12/15
•C20/25
•C30/37
•C32/40
•C35/45
•C40/50
•C50/60
•C55/67
•C60/75
•C70/85
•C80/95
•S235
•S275
•S355
•S460
•High Strength Concrete

PileType

•Driven
•Bored
•Jacked in

 

Structural Parameters
IFC-SG PropertyList

ReinforcementLength

•Fully reinforced
•Unreinforced
•Any numerical value [up to 1 decimal place]

ReinforcementSteelGrade

 

•500A
•500B
•500C
•600A
•600B
•600C

SectionFabricationMethod

•Hot rolled
•Cold formed

SlabType

 

•One way
•Two way
•Cantilever
•Flat slab
•Flat slab with drop panel
•Transfer Slab

StirrupsType, StirrupsTypeLeft, StirrupsTypeMiddle, or StirrupsTypeRight

 

•Normal
•U
•C
•CL [for civil defence shelter]
•Torsion

Abbreviation List:

CIS   - Cast in situ

PC  -   Precast works

PT (Pre)  - Pre-tensioning works

PT (Post)   - Post-tensioning works

PF  - Prefabrication (e.g. steel, MET, etc.)

PPVC  - Precast-Prefabricate-Volumetric Component

 

Link: IFC-SG Resource Kit

See also: Preparing models for submission