What does this mean?
The Model Checker checks whether the IFC file
contains at least one IfcSite
entity.
An IFC file without an IfcSite will be flagged.
The expected spatial hierarchy for a typical
building model is shown below.
✓ Expected hierarchy
IfcProject
IfcSite
IfcBuilding
IfcBuildingStorey
Building elements
! Missing IfcSite
IfcProject
IfcSite missing
IfcBuilding
IfcBuildingStorey
For CORENET X submission, it is recommended
to maintain only one IfcSite
under the IfcProject
to ensure a consistent spatial hierarchy.
Likely cause
The IFC export settings in the BIM authoring
software may not be configured correctly,
resulting in the IfcSite entity being omitted
from the exported IFC file.
How to troubleshoot
-
Open the IFC file in an IFC viewer and
review the spatial hierarchy to confirm
that an IfcSite is present.
-
Review the recommended IFC+SG export
settings for the BIM authoring software.
-
Re-export the IFC file and run the
Model Checker again.
View BIM authoring tool settings ↗