Agency Specific Modelling Requirements
Structural Parameters | |
IFC-SG Property | List |
BeamSpanType | •Single •End •Interior •Cantilever |
ConnectionTypeBottom, ConnectionTypeTop, LeftConnectionType, or RightConnectionType | •Pinned •Fixed •Free • |
ConstructionMethod | •CIS •PC •PT (Pre) •PT (Post) •PF •PPVC •Spun [for pile element only] |
MaterialGrade | •C12/15 •C20/25 •C30/37 •C32/40 •C35/45 •C40/50 •C50/60 •C55/67 •C60/75 •C70/85 •C80/95 •S235 •S275 •S355 •S460 •High Strength Concrete |
PileType | •Driven •Bored •Jacked in |
ReinforcementLength | •Fully reinforced •Unreinforced •Any numerical value [up to 1 decimal place] |
ReinforcementSteelGrade | •500A •500B •500C •600A •600B •600C |
SectionFabricationMethod | •Hot rolled •Cold formed |
SlabType | •One way •Two way •Cantilever •Flat slab •Flat slab with drop panel Transfer Slab
|
StirrupsType, StirrupsTypeLeft, StirrupsTypeMiddle, or StirrupsTypeRight | •Normal •U •C •CL [for civil defence shelter] Torsion
|
Abbreviation List:
CIS - Cast in situ
PC - Precast works
PT (Pre) - Pre-tensioning works
PT (Post) - Post-tensioning works
PF - Prefabrication (e.g. steel, MET, etc.)
PPVC - Precast-Prefabricate-Volumetric Component
The following fire safety equipment / provision need not be shown in the model. |
•Equipment, furniture, fixture (e.g. lighting, fans) •Wiring connecting various system in building |
The following fire safety equipment / provision need not be modelled in full. They can be represented by suitable objects. If the equipment / provision is applicable only to Independent Submission, they can be represented in 2D. | |
•Signage (exit staircase numbering, evacuation lift, re-entry floor, etc) •Signage for “PWD Holding Point” •Mean of communication between PWD holding point and FCC/24 hourly manned station. •Override device •Fire stopping material (for filling gap) •Composite panel •Hose reel drum (excluding cabinet/enclosure) •Breathing apparatus cabinet/enclosure (for Total flooding fire extinguishing system) •Generator/emergency generator/standby generator •transformer •Fire extinguisher •Housing cabinet/enclosure •Main fire alarm panel/cabinet •Sub fire alarm panel/cabinet •Manual call point •Standby hose cabinet/enclosure •Bell for manual alarm •Vision alarm – strobe light •Smoke/heat detector •Home Fire Alarm Device (HFAD) •Video Image Fire Detection System (VIFDS) •Sprinkler head •Sprinkler control valve | •Fire pump & control panel •Fire water tank •Compressed cylinders & discharge nozzle for Water mist system •Compressed cylinders & discharge nozzle for fixed automatic fire extinguishing systems (e.g kitchen suppression system, GM200, etc) •Fire lift switch •Evacuation switch •Intercom system in fire lift •CCTV camera •Lift control panel •Lift car •Standby fans/ multiple fans •Fire damper •Smoke damper •Air-handling unit •Air conditioner compressor + unit •Exit/directional exit sign (high level and low level) •Need to provide arrow if for directional exit sign •Emergency lighting •Photoluminescent marking •Equipment/services in Fire Command Centre mentioned in Cl. 8.2.4b. •Speakers for public address system/emergency voice communication system •Handset/cabinet/enclosure (for emergency voice communication system) |